Electrolytic cell replacement for Salt Filtration system.

  • This unit has a smaller 1.50" O-ring at one end and a larger 3.25" O-ring on the other end.
  • This is a Titanium Diaphragm metal Cell

Replacement Part info Key #2 in 2017 manual

  • No warranty

Our stock quantities are based on retailer supply and demand. This Electrolytic Cell is no longer being made, and will no longer be available to purchase.
  • If the Cell status lights on the Salt unit are Orange or Red the Electrolytic Cell may be cleaned with normal soapy water or vinegar to help extend the life of the Cell unit.
  • If the Cell status lights on the Salt unit are still Orange or Red after cleaning the cell unit; then the Cell needs to be replaced.
  • Under normal conditions the cell units will need to be replaced approximately every 3 months or 9600 hours. (Depending on usage.)
  • Please note that incorrect Salt purity will affect performance or the life of salt system. We recommend to use only Sodium Chloride (NaCl) salt that is at least 99.8% pure.
  • This unit plugs in to the main Control box and has two different style plugs. (One jack style plug & one two prong plug)
  • Please make sure to replace the connecting plugs into their corresponding plastic slots before trying to connect the main cap back on.
  • If the cell is not producing chlorine, disconnect the plugs and reconnect tightly to make sure there is a good connection between the cell and the main unit.
  • This Electrolytic cell has no warranty.
Electrolytic Cell
Salt Cell Replacement
Electrolytic cell unit

  • This unit plugs in to the main Control box with two different plugs. (One jack plug & one two prong plug)
If the consumer is having trouble with their cell unit have them disconnect the plugs and then reconnect and try again, as it may not be making a good contact.

  • Please make sure to replace the plugs back into their corresponding plastic slots before trying to connect the cap back on.
  • This is a Titanium Diaphram metal Cell
  • The Electrolytic Cell itself uses 12V of Electricity.
  • This unit has a smaller 1.5" O-ring at one end and a larger 3.25" O-ring on the other end.
  • The salt cell life is 9,600 hours
See below for O-rings

Please note the color of the Electrolytic cell metal piece is different color than before (blue) , because it is from another supplier, but does not affect performance and assembly.
  • IMPORTANT: The Electrolytic Cell has an AUTOMATIC self cleaning function incorporated into the electronic control program.
  • The system automatically checks operational cell efficiency. If the system indicates "Poor Cell Condition" check the pool water quality first.
  • If the water quality is good and the "CELL STATUS" LED is still ORANGE or RED, then CLEAN the Cell unit.
  • The Cell may be cleaned with normal soapy water or vinegar to help extend the life of the Cell unit.
  • If the "CELL STATUS" LED is still ORANGE or RED after cleaning the cell unit; then the Cell needs to be replaced.
  • If the consumer is under warranty please follow normal warranty procedures, if the consumer is outside of their warranty they will need to purchase cell units approximately every 3 months depending on usage. (The salt cell life is 9,600 hours)